Description
25HCC560A003
25H = Performance Series Heat Pump with Puron Refrigerant
C = Performance
C = Puron
5 = 15 SEER
60 = 60,000 Btuh
A = Standard Grille
0 = Not Defined
0 = Not Defined
3 = 208/230 ---1
25H = Performance Series Heat Pump with Puron Refrigerant
C = Performance
C = Puron
5 = 15 SEER
60 = 60,000 Btuh
A = Standard Grille
0 = Not Defined
0 = Not Defined
3 = 208/230 ---1
Standard Features
- Up to 16 SEER cooling efficiency
- Up to 9 HSPF heating efficiency
- Sound: as low as 68 decibels
- Compressor sound blanket
- Filter drier system protection from moisture and contaminants
- WeatherArmor™ Ultra protection
- Non-ozone depleting Puron® refrigerant
- 10-year parts limited warranty1
Optional Features
- Optional labor warranty available
1See warranty certificate for complete details
Specifications
- BrandCarrier
- BrandCarrier
- CFM4046
- CoastalFalse
- Compressor Stage1
- ConfigurationVertical
- Cooling Capacity57000
- FamilyPerformance
- Line Voltage (60Hz)240V
- Nominal Seer15
- RefrigerantR410A
- Suction Line Size1-1/8"
- Tonnage5
- Voltage (Phase)208/230 V 1-Phase
- CFM Nominal4046
- Coil Guard TypeLouver
- CompressorScroll
- Compressor RLA26.4
- Compressor TypeScroll
- Condenser Motor HP1/4
- Condenser Motor RPM825 rpm
- Condenser Motor Speeds1 - Speed
- Condenser Motor TypePermanent Split Capacitor
- EER12, 12.5
- Fan Diameter26
- Frequency60
- Full Load1.2 amp
- Heating Capacity35200, 56500
- Height42.75 in
- High PressureTrue
- High Pressure SwitchTrue
- HSPF8.5
- InverterFalse
- LEED CertifiedFalse
- Length35 in
- Liquid Line FittingSweat
- Liquid Line Size3/8
- Liquid Line Size3/8 in
- Locked Rotor134 amp
- Low PressureTrue
- Low Pressure SwitchTrue
- LRA134
- Max Sound Level73
- Maximum Circuit Breaker50
- Maximum COP3.84
- Maximum EER12.5
- Maximum Fuse Size50 amp
- Maximum Heating Capacity56500
- Maximum Piping Length250
- Maximum SEER15
- Maximum Voltage253
- MCA34
- Metering DeviceTXV
- Metering Device HeatingPiston
- Minimum Ambient Temperature-20 °F
- Minimum Cooling Capacity55500
- Minimum EER12
- Minimum Heat Efficiency HSPF8.2
- Minimum Heating Ambient Temperature-20
- Minimum Heating Capacity35200
- Minimum SEER14
- Minimum Voltage197
- Motor Phase1
- Number Of Fan Blades3
- Outdoor Fan Motor FLA1.2
- Outdoor FPI20
- Package Quantity1 ea
- Rated Load26.4 amp
- Rows2
- SEER15
- Shipping Height43.375 in
- Shipping Length37.125 in
- Shipping Point38017
- Shipping Weight345 lb
- Shipping Width37.125 in
- Sound BlanketTrue
- Sound BlanketTrue
- Sound Level73 dBA
- Suction Line FittingSweat in
- Suction Line Size1 1/8
- UL ListedTrue
- UL RecognizedTrue
- Voltage208/230
- Weight294 lb
- Width35 in
Equipment Parts List