HOT SURFACE IGN MODULE


HOT SURFACE IGN MODULE
Description
ICM Controls 20 to 120 VAC 60 Hz, 4 or 7 Sec Ignition Trial, 32 Sec Prepurge, 1.5 Sec Flame Failure Response, Natural/Liquid Propane Gas, Single/Dual Rod Flame Sense, Hot Surface Ignition Control
Features & Benefits
- Hot Surface Ignition (HSI) Module
- Single/Dual Rod Sensing Capabilities
- For Gas Fired Furnaces, Boilers and Other Heating Appliances
- Switch Selectable Lockout Times, Ignition Trials
- Works with Both Natural and LP Gas Systems
- Diagnostic LED to Aid in Troubleshooting
- Made in USA
Specifications
- Fuel Type: Natural/Liquid Propane Gas
- Flame Sense Type: Single/Dual Rod
- Ignition Source: Hot Surface
- Ignition Trial Time: 4 or 7 Second
- Prepurge Time: 32 Second
- Flame Failure Response Time: 1.5 Second
- Valve Rating: 2 Amp at 24 Volt
- Power Rating: 20 to 120 Volt AC 60 Hertz
- Size: 4 Inch Length x 5.375 Inch Width x 1.625 Inch Height
- Temperature Rating: -40 to 175 Deg F
- Application: Gas Fired Furnace, Boiler, Heating System
- Ignition Trials to Lockouts 1 or 3 Second
Documents
Specifications
- BrandICM Controls
- BrandICM Controls